Эротические рассказы

Plastics Process Analysis, Instrumentation, and Control. Группа авторовЧитать онлайн книгу.

Plastics Process Analysis, Instrumentation, and Control - Группа авторов


Скачать книгу
magnetic data described by a three parameter modified Fröhlich equation fitted to the magnetic saturation curve, and solved with an iterative procedure.

      The numerical calculations were compared with experiments conducted with two types of induction coils built into the injection molding tool. The model shows a very good agreement with the experimental temperature measurements (35).

      It could also be shown that the nonlinearity can be used without the temperature dependency in some cases, and a method was proposed for estimating an effective linear permeability to use with simulation codes that are unable to utilize a nonlinear solver (35).

      Multi-turn Induction Heating Coil. An integrated multi-turn induction heating coil has been developed and was assembled into an injection molding tool. This tool contained a glass window, so the effect of induction heating can directly be captured by a high speed camera. In addition, thermocouples and pressure sensors are also installed, and together with the high speed videos, the induction heating and filling of the cavity is compared and validated with simulations.

      Two polymer materials, i.e., ABS and high viscosity PC, were utilized during the injection molding experiments. A nonlinear electromagnetic model was used to establish an effective linear magnetic permeability. The three-dimensional transient thermal field of the mold cavity was then calculated and compared with the experiments. This thermal field was transferred to an injection molding flow solver to compare the simulations and experimental results from the high speed video, both with and without the effect of induction heating.

      A rapid thermal cycle was proved to be feasible in a mold with an integrated induction coil. Furthermore, it was shown that the process can be modeled with good accuracy, both in terms of the thermal field and in terms of the flow pattern (34).

      High-Frequency Induction Heating. The recent trends of miniaturization and multifunctionality in electrical parts have driven the development of molded interconnect devices (MIDs) that contain conductive tracks on a nonconductive base (36).

      A polymer/metal hybrid molding technology was developed to fabricate MIDs in a single manufacturing process, without an additional assembly procedure. For this purpose, injection molding was performed to fabricate a thermoplastic carrier that contained negative circuit channels, and die casting was used to fill the circuit channels with metal alloy of low melting point. To increase the flow length of the molten metal through the narrow circuit channel, high-frequency induction heating was used prior to the die casting stage.

      Injection molding is a well-established replication process for the cost-effective manufacture of polymer-based components (37). The process has different applications in the medical, automotive and aerospace fields among others. To expand the use of polymers to meet growing consumer demand for increased functionality, advanced injection molding processes have been developed that modify the polymer to create microcellular structures.

      Using the creation of microcellular materials, additional functionality can be gained through polymer component weight and processing energy reduction. Microcellular injection molding shows a high potential for creating green manufacturing platforms (37).

      The process conditions as well as nano/micro-fillers such as nanoclay and core-shell rubber have a strong influence on cell density and cell size, hence, the final material properties of the molded parts (38). The addition of nano/micro-fillers at optimum loading levels can generally facilitate the formation of microcellular plastics with higher cell density and smaller cell size, leading to superior mechanical properties.

      The integration of a solid plastic surface with a microcellular plastic core via the co-injection molding technique has been investigated to achieve Class A surfaces and improved material performance. An improved mathematical model has been developed to simulate the cell growth behavior in the microcellular injection molding process (38).

      For cooling a heated mold, a conventionally known mold-cooling system can supply a cooling medium, such as cooling water, to a medium flow path for a mold. In such a mold-cooling system, there has been a problem of the cooling medium supplied to the medium flow path of the mold heated to a high temperature being gasified in the medium flow path and the vapor being discharged.

      In order to solve the above-mentioned problem, a mold-cooling system for cooling a heated mold has been developed. This system supplies a cooling medium from a cooling medium supply source to a medium flow path provided for a mold, and a discharge side path connected to an outlet side of the medium flow path of the mold that can be communicated with a heat exchanger condensing the cooling medium gasified and discharged from the medium flow path.

      The mold-cooling system is constituted in such a manner that a discharge side path 15 connected to an outlet 5 side of the medium flow path 4 of the mold 2 is communicated with a heat exchanger 20 condensing gasified cooling medium discharged from the medium flow path 4.

Schematic illustration of mold-cooling system.

      The temperature sensor 6 can be constituted so as to detect the temperature of medium (cooling medium) on the outlet 5 side, a vicinity region of the outlet 5 of the medium flow path 4, a downstream vicinity region of the outlet 5, or the like. The mold 2 is provided with a mold heater 7 as a means of heating the mold


Скачать книгу
Яндекс.Метрика