to direct their research toward examining posterior wall stress for clinical relevance. One of the first studies to apply the finite element analysis (FEA) to determine the AAA wall stress was the study of [37] who concluded that FEA has a potential of becoming a crucial tool in the study of vascular mechanics. Their study was followed by extensive research in the area of numerically predicted AAA wall stress that continues even at present. However, limitations of this study include the use of idealized models with regular structures and evenly distributed wall stress.

      Venkatasubramaniam et al. [10] refuted traditional views that relate aneurysm size to the risk of rupture. They conducted a comparative study of aortic wall stress in ruptured and non‐ruptured aneurysms with an aim to prove the importance of wall stress when predicting the risk of rupture in individual patients. Namely, the study included computed tomography (CT) scans of 27 patients (12 ruptured and 15 non‐ruptured AAA), predominantly males. Using the finite element method, they calculated wall stress using the geometry of AAA, the material properties of the aortic wall, and the forces and constraints acting on the wall. The material properties were used from a previously validated mathematical model by [39–41]. ANSYS 6.1 program (ASN Systems Ltd, Cannonsburg, USA) was utilized for the analysis and post‐processing while the von Mises stress was used to evaluate the state of the aneurysms. There were no important differences in the mean diameter between two groups (6.8 cm for non‐ruptured and 7.6 cm for ruptured, P > 0.1) and there were two aneurysms that ruptured at small diameters of 5.0 and 5.7 cm. The authors concluded that AAA that ruptured or went on to rupture had significantly higher peak stress (mean 1.02 MPa) compared with non‐ruptured (mean 0.62 MPa). Moreover, systolic blood pressure was also significantly higher in ruptured AAA. Noting that 45 and 65 mm diameter AAAs can have the same stress, they emphasized the role of the shape and asymmetry of the aneurism including the anterior and superior limits. They also demonstrated that wall stress can be calculated from a routine CT scan and that it may be a better predicator of AAA risk of rupture than diameter alone on the individual basis. On the other hand, the study assumed a uniform AAA wall thickness of 2 mm and did not take into account the effect of thrombus on wall stress.

      In 2006, Vande Geest et al. [42] developed a biomechanics‐based rupture potential index (RPI) that became a useful rupture prediction tool. Namely, the RPI predetermined the wall strength on a patient‐specific basis by utilizing experimental tensile testing and statistical modeling. The tissue strength was calculated by taking parameters such as age, sex, smoking status, family history of AAA, normalized diameter, and the maximum thickness of the ILT into account. Then, the wall stress was predicted with FEA. Although the authors reported that the RPI has a potential to identify high rupture risk of AAA better than diameter or peak wall stress (PWS) alone, their approach still requires validation before it can be introduced into clinical setting.

      Finol and Ender [45, 46] used a Spectral Element Method with three‐step time splitting scheme for the semidiscrete formulation of the time‐dependent terms in the momentum equations for axisymmetric two‐aneurysm abdominal model. This methodology has been widely used for the Direct Numerical Simulation of transitional flows with fast‐evolving temporal phenomenon and complex geometries.

      Multi‐scale models for AAA are considered constitutive models for vascular tissue, where collagen fibers are assembled by proteoglycan cross‐linked collagen fibrils (CFPG‐complex) and reinforce an otherwise isotropic matrix (elastin). There is multiplicative kinematics for the straightening and stretching of collagen fibrils. Mechanical and structural assumptions at the collagen fibril level define a piece‐wise analytical stress–stretch response of collagen fibers.

      The concept of multi‐scale constitutive model performs integration at the material point for macroscopic stress which takes into account micro plane concept incorporated in the finite element modeling (FEM) [47, 48].

      Zhang et al. [49] used multi‐scale and multi‐physical models for understanding disease development and progression, and for designing clinical interventions. They investigated multi‐scale models of cardiac electrophysiology and mechanics for diagnosis, clinical decision support, and personalized and precision medicine in cardiology with examples in arrhythmia and heart failure.

      FSI describes the wave propagation in arteries driven by the pulsatile blood flow. These problems are complex and challenging due to the high nonlinearity of the problem. The nonlinearity exists in the fluid equation but also in the structure displacement which modifies the fluid domain and generates geometrical nonlinearities as well [50].

      All the above studies demonstrate the importance of biomechanical modeling of AAA by using FEM approach with and without FSI and nonlinear wall deformation. This mechanical approach provides an additional understanding of potential indicators of rupture risk.

      Experimental tests are used to determine the mechanical properties of AAA. In‐vivo measurements are based on the imaging modality. For in‐vivo measurements, the main difficulty is to accurately determine the true force and the displacement distribution for the aorta wall. For isolating samples