Эротические рассказы

Computational Modeling and Simulation Examples in Bioengineering. Группа авторовЧитать онлайн книгу.

Computational Modeling and Simulation Examples in Bioengineering - Группа авторов


Скачать книгу
behavior affecting the results of such tests. MacSweeney et al. [62] found that elastic modulus was higher in aneurysmal abdominal aorta compared with controls. More recently, van't Veer et al. [63] estimated the compliance and distensibility of AAA by means of simultaneous instantaneous pressure and volume measurements obtained with the magnetic resonance imaging (MRI). Ganten et al. [64] by using time resolved electrocardiography (ECG)‐gated CT imaging data from 67 patients, found that the compliance of AAA did not differ between small and large lesions. Molacek et al. [65] did not find any correlation between aneurysm diameter and distensibility of AAA wall and of normal aorta. Uniaxial extension testing is the simplest and most common of ex‐vivo testing methods. The recorded force‐extension data are converted to stress/strain. Di Puccio et al. [66] provided a recent review of the incompressibility assumption on soft biological tissue. Biaxial test was used as an initial square thin sheet of material which is stress normally to both edges. Even this test is not sufficient to fully characterize anisotropic materials [67, 68], although it can capture additional information regarding the mechanical behavior of the specimens with respect to uniaxial one.

      One of the most complete data for biaxial mechanical behavior of aorta and AAAs is described in Vande Geest et al. [69, 70]. They reported on biaxial mechanical data for AAA (26 samples) and normal human AA as a function of age: less than 30, between 30 and 60, and over 60 years of age. They found that the aortic tissue becomes less compliant with age and that AAA tissue is significantly stiffer than normal abdominal aortic tissue.

      Ex‐vivo testing is mostly based on uniaxial or biaxial stretching of the intraoperatively harvested tissue specimens. These tests have the ability to characterize intrinsic properties of the tissue itself with independent physical meanings, stiffness, failure stress, and strain. Tissue sample is exposed to extension along its length at a constant displacement rate, while the force is recorded during extension and until failure of the tissue. Uniaxial extension testing is the simplest and most common. Van de Geest et al. [72] reported uniaxial extension testing of 69 AAA specimens, from 21 patients. A novel mathematical model to estimate physically meaningful measures such as stiffness varied from 21.2 to 19.3 N/cm2, mean 80.5 N/cm2.

      Improvement of uniaxial testing was achieved by performing biaxial testing, when specimen is exposed to determined forces between the two orthogonal directions. Using biaxial testing, the same authors compared the tissue of AAA and normal aorta and compared their behavior in longitudinal and circumferential direction. They found that aneurysmal degeneration of the abdominal aorta is associated with an increase in mechanical anisotropy, with preferential stiffening in the circumferential direction. Information related to stiffness and strain of aortic tissue was gained. Thubrikar et al. [73] were testing different regions of aneurysm in terms of yield stress, yield strains, and other mechanical properties, and found that the anterior wall of AAA is the weakest. In the circumferential direction, the yield stress of the lateral region was greater than that of the anterior or posterior region (73 + 22 N/cm2 versus 52 + 20 N/cm2 or 45 + 14 N/cm2, respectively).

      Our results showed rupture of the tissue at the inflation pressure of 9.8 N/cm2. The analytical calculated wall strength for wall thickness 0.2 cm and aorta radius 1 cm was 24.5 N/cm2. FEA showed PWS of 57 N/cm2 and wall stress of 21.2 N/cm2 at the anterolateral wall of AAA in the area of harvested tissue [71].

      It is very important to use arterial wall with proper material model because the wall stiffness increases when lumen diameter increases and calcification and medial sclerosis occur with aging and disease. The aneurysmal wall has been found to be mechanically anisotropic [74]. Isotropic properties assumption is a reasonable assumption in most cases. A more accurate constitutive model is needed to describe the properties of the wall.

      Most aneurysms have ILT within their lumen. Stenbaek et al. [82] described that the development of ILT may be a better predictor than the maximum diameter of the AAA as a rupture risk parameter. Li et al. [83] calculated that the non‐ILT models had higher stress development than the ILT models. Di Martino and Vorp [84] found that ILT might protect the AAA wall from the pressure applied by blood flow. O'Leary et al. [85] performed mechanical tests on 356 samples and classified them into 3 morphologies, type 1 which was a multilayered ILT which strength and stiffness decreased gradually, type 2 which strength decreased abruptly, and a single‐layered ILT with lower strength and stiffness compared with the other two types. Tong et al. [86] carried out biomechanical behavioral studies on 90 AAA samples (78 men and 12 women). They found that the female ILT luminal layer showed a lower stiffness in the longitudinal direction than male and, consequently, the thrombi may have different wall weakening effects in males and females. Speelman et al. [87–89] also showed that AAA wall stress is closely related to the AAA diameter. Namely, they investigated whether wall stress can be used to predict stable and progressive AAAs as well as the effect of ILT on wall stress. The study was conducted on the finite element models of 30 patients with wall stresses


Скачать книгу